Get a Quote or Order
Send us these details and we'll respond the same business day.
- Flange rating (150# to 2500#) and size
- Face type: mill or serrated (RTJ on request)
- Isolation or hydrotest service
- Channel depth, if deeper than 1/4"
- Material
- Quantity and date needed
| Specification | Details |
|---|---|
| Sizes | 1/2" – 96" |
| Rating Classes | 150# • 300# • 600# • 900# • 1500# • 2500# |
| Standard Thickness | 1/2" (isolation service; hydrotest version available) |
| Purge Channels | 1/4" deep • 3/4", 1", or 1-1/2" wide (by size) |
| Purge Area | ~50% of gasket area (protects the seal) |
| Handle | "P" Cut (identifies a purge blind in the line) |
| Face Types | Mill • Serrated (125/250 RMS) • RTJ (on request) |
| Stocked Alloys | 516-Gr70 CS • 304/316 SS (Any Available Alloy) |
| Materials Origin | USA |
| Coating Options | Various |
| Availability | Rent • Purchase |
What Is a Purge Blind?
A purge blind isolates the line like a standard slip blind, but the purge side of the disc has milled channels that run to the outside edge. With the flanges bolted up, purge gas flows through the channels, giving you a controlled standoff at the flange instead of a gap forced open by hand.
Also known as:
Replaces the Old Way of Purging
What Are Purge Blinds Used For?
- Line purging: purge gas in or out at the flange while the line stays isolated
- Weld purging: inert gas shielding for clean, high-quality welds, protected from the atmosphere
- Maintenance isolation: keeps the rest of the system online during targeted work
Standard EZ Purge blinds are for isolation only. For hydrotesting, order the hydrotest version, built with a thicker non-purged side.
Channel & Purge Specs
"P" Cut Handle
Every EZ Purge handle has a "P" cut so crews can spot a purge blind in the line at a glance. Blinds are indent marked with size, rating, and material, and edges are polished smooth.
Handles Color-Coded by Class
Carbon steel handles are painted to standard flange rating colors.
Material
EZ Vent-Purge® Combination
Purge channels and a vent port in one blind. The EZ Vent-Purge® combines the EZ Purge and EZ Vent® in a single specialty blind.
Why USA Industries EZ Purge® Blinds
We are the actual manufacturer, not a distributor. We've built isolation blinds in-house since 1982, so channel depth, thickness, and face are engineered to your spec, with 24/7/365 emergency service from S. Houston TX, Corpus Christi TX, Prairieville LA, and Broken Arrow OK.
EZ Purge FAQ
Can I hydrotest against the non-purged side?
Not with a standard blind, which is designed for isolation only. Tell us when you order and we'll build a hydrotest version with a thicker non-purged side.
Are EZ Purge blinds available for rental?
Yes, for rental or purchase. See rentals.
Can you provide documentation proving material origin?
Yes. Mill test reports (MTRs) and country of origin documentation are available on request.
